Product Details:
Payment & Shipping Terms:
|
Accuracy: | +/-10mm | Diameter: | M18x80 |
---|---|---|---|
Material: | Brass,nickel-plated Housing | Color: | Silver |
Selling Units: | Single Item | Single Package Size : | 29X29X25 Cm |
Single Gross Weight: | 60 G | Package Type: | Carton |
High Light: | 300kHz Ultrasonic Waterproof Sensor,Brass Long Range Ultrasonic Sensor |
High Accuracy Ultrasonic Sensor Level Measurement With Pipe Stainless steel Housing
Highlights
Ultrasonic sensor Ultrasonic sensor UM500-18GM-SP
Technical data | |
General Specifications | |
Sensing distance 40…450mm(30---350mm) | |
Adjustment range 40…450mm(30---350) | |
Unusable area 0…40mm(0---30mm) | |
Standard target plate 100mm×100mm | |
Transducer frequency About 300 kHz | |
Response delay About 125ms | |
Indicators/Operating means | |
LED yellow solid: object in evaluation range |
|
LED red flashing: fault or program function object not detected | |
Electrical specifications | |
Operating voltage UB 10…30VDC,ripple10%ss | |
No-load supply current ≤20mA | |
Output | |
Output type 1 switch output E4,NPN NO/NC,programmable | |
Resolution 0.11mm at max.sensing range |
|
Deviation of the characteristic |
|
Repeat accuracy ±0.1% of full-scale value | |
Load impedance >1k Ohm |
|
Temperature influence ±1.5% of full-scale value | |
Ambient conditions | |
Ambient temperature -25…70℃ | |
Storage temperature -40…85℃ | |
Mechanical specifications | |
Protection grade IP67 | |
Connection Connector M12x1,4-PIN |
|
Material |
|
Transducer epoxy resin/hollow glass sphere mixture; Polyurethane foam |
|
Weight 60g |
|
Standard conformity EN 60947-5-2:2007 |
Adjusting the switching points
The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - UB or + UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s.LEDs indicate whether the sensor has recognised the target during the TEACH-IN procedure. Switching point A1 is taught with - UB,A2 with +UB. Five different output functions can be set.
Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 mins when power
on. If want to change the switching point, the user can only setting the request distance after power restart.
TEACH-IN window mode,normally-open function |
|||
TEACH-IN window mode,normally-closed function |
|||
TEACH-IN switching point, normally-open function |
|||
|
|||
TEACH-IN switching point, normally-closed function |
|||
TEACH-IN detection of objects presence |
|||
Default setting of switching point |
|||
LED displays | |||
Displays in dependence on operating mode | Red LED | Yellow LED | |
TEACH-IN switching point |
off flashes On |
flashes off off |
|
Normal operation | off | Switching state | |
Fault | on | Previous state |
Installation conditions
If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.
Contact Person: Dream Chan
Tel: 86-755-83747109