                    Product Details:
 Payment & Shipping Terms:
  | 
                            
| Accuracy: | +/-10mm | Material: | ABS,PZT | 
|---|---|---|---|
| Color: | Green | Selling Units: | Single Item | 
| Single Package Size : | 29X29X25 Cm | Single Gross Weight: | 20.000 Kg | 
| Package Type: | Carton | ||
| Highlight: | long distance ultrasonic sensor,ultrasound distance sensor | 
			    	||
High Accuracy Ultrasonic Sensor Distance Measurement With ABS Housing
Highlights
| Technical data | |
| General Specifications | |
| Sensing distance | 100…1000mm | 
| Adjustment range | 200…4000mm | 
| Unusable area | 0…80mm | 
| Standard target plate | 100mm×100mm | 
| Transducer frequency | |
| Response delay | About 195ms | 
| Indicators/Operating means | |
| LED blue | Power on | 
| LED yellow | Flashing:program function object detected | 
| LED red | permanently red: Error Red,flashing:object not detected | 
| Electrical specifications | |
| Operating voltage UB | 
			 10 … 30 V DC 
			4.2 … 5.5 V DC 
			 | 
		
| No-load supply current | ≤20mA | 
| Electrical Interface | PVC cable | 
| 
			 Dimensions 
			 | 
			36 X 56 X 26 | 
| Output | |
| Output type | 
			 1 switching PNP output 
			1 analog output 
			(current or voltage) 
			1 digital output 
			(RS232/485 or UART 
			TTL) 
			 | 
		
| Rated operational current | 200mA,short-circuit/overload protected | 
| Default setting | 80mm----0V/4mA, 2000mm----10V/20mA | 
| Voltage drop | ≤ 3V | 
| Repeat accuracy | ≤ 1% | 
| Switching frequency f | ≤ 4HZ | 
| Range hysteresis H | 1% of the set operating distance | 
| Temperature influence | ± 1.5% of full-scale value | 
| Ambient conditions | |
| Ambient temperature | 
			 -40°C to 70°C 
			 | 
		
| Storage temperature | -40…85℃(233...358K) | 
| Mechanical specifications | |
| Protection grade | IP68 | 
| Connection | V1 connector(M12×1),4-pin | 
| Material Housing | ABS | 
| Transducer | 
			 epoxy resin/hollow glass sphere mixture; foam polyurethane,cover PBT  | 
		
| 
			 configuration 
			 | 
			
			 Command(digital output) 
			 | 
		
| 
			 Electrical Interface 
			 | 
			
			 M12-4PIN 
			 | 
		
| Standard conformity | 
			 EN 60947-5-2:2007 IEC 60947-5-2:2007  | 
		
Installation conditions
If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.
V1 Connector
Contact Person: Dream Chan
Tel: 86-755-83747109